HOME > ブログ > bluesky123のブログ >  steering and electrical circuit belonging to the motor

◆bluesky123のブログ◆
steering and electrical circuit belonging to the motor

The industrial valves are usually in the fluid system. These devices used to control the direction, pressure, and flow from the fluid is the device so that the flow and stops of the medium (liquid, gas, powder) inside the pipe and equipment and can control its flow. The valve will be fluid delivery system. Important control components at the center.



A detailed explanation with the correct operation of your industrial valves



List of content because of this article:

1. Preparation in advance of operation.

2. Correct functioning of manual valves.

3. Correct operation of your safety valve.

4. Correct operation with the trap

5. Correct operation of the pressure reducing valve

A FEW. Correct operation of the check valve



Preparation prior to operation



Read the performing instructions carefully before performing the valve. Be sure to understand the flow direction in the gas before the function. Pay attention to test the valve opening in addition to closing mark. Check the appearance on the valve to see if the valve is damp. If its wet, it should become dried. If it is found to own other problems, it really should be handled in time. In the event the electric valve is deactivated for further than 3 months, check out the clutch before starting. After confirming that the handle was in the manual position, check out the insulation, steering and electrical circuit belonging to the motor.



Correct operation involving manual valves



The manual valve is a most widely used valve. Its handwheel or handle is created according to the typical manpower, taking into account the strength with the sealing surface and the required closing force. Therefore, you can not use long levers or long wrenches to go. Some people are accustomed to having wrenches, should be strictly spotted when opening the valve really should be used to stabilize your force, to avoid abnormal force, resulting in beginning and closing valves, the force need to be stable, not impact. Some components of high-pressure valves that have been opened and closed by impact are considered such that the impact force is not equal to that of an general valve.



When this valve is fully open up, the handwheel should be reversed a bit to make the threads tightly tight in avoiding loose damage. For open-end valves, remember the position of your stem when fully open and fully closed to prevent hitting the top dead center when fully open. And it is easy evaluate whether it is natural when fully closed. If your valve is detached or large debris is embedded between the valve plug seals, the position in the valve stem will switch when fully closed. Destruction of the valve sealing outside or valve handwheel.



Valve opening sign: Ball control device, butterfly valve, plug valve The groove on the top surface of that valve stem is parallel towards channel, indicating that the valve is within the fully open job; when the valve stem is rotated 90 for the left or right. If the groove is perpendicular towards the channel, the valve is due to the fully closed location. Some ball valves, butterfly valves, and plug valves are usually opened in parallel while using wrench and closed vertically. The operation in the three-way and four-way valves should be carried out according for the markings of opening, concluding and reversing. The active handle must be removed after the functioning.



Correct operation of the safety valve



The safety valve is put through pressure test and continual pressure before installation. When the safety valve is running for long periods, the operator should focus on check the safety control device. When checking, the human being avoids the safety valve outlet, checks the health and safety valve seal, and raises the safety valve using the wrench by hand. Remove dirt and verify the flexibility on the safety valve.



Correct operation belonging to the trap



The trap is a valve that is definitely easily blocked by water and stuff like that. When enabled, first wide open the flush valve and flush the tubing. If you find a bypass, the bypass valve is often opened for a brief flush. There is no trap with the flushing tube and your bypass tube. The trap is often removed. After the cut-off flush is switched on, the shut-off valve is definitely closed, the trap can be installed, and then the shut-off valve is showed to activate the capture method.



Correct operation of your pressure reducing valve



Ahead of the pressure relief valve is actually activated, the bypass valve or flush valve must be opened to clean the pipeline. After the pipeline will be flushed, close the get around valve and flush valve, and then activate this pressure relief valve. Some steam pressure reducing valves employ a steam trap while in front of them, need to become opened first, then slightly open the shut-off valve following a pressure reducing valve, and finally open the shut-off valve while you're watching pressure reducing valve, watch the pressure gauge before and following on from the pressure reducing valve, adjust the pressure reducing valve Adjust the screw to ensure the pressure behind your valve reaches a predetermined value, then slowly open the shut-off valve following the pressure reducing valve, and correct the pressure following a valve until it is satisfactory. Fix the adjusting screw and cover that protective cap.

If the pressure decreasing valve fails or should be repaired, the bypass valve really should be opened slowly, and the valve must be shut off before concluding the valve. The bypass valve needs to be adjusted manually to make the pressure in the pressure reducing valve in essence stabilize above and below the predetermined value, then close. After the demand reducing valve is exchanged or repaired, it will come back to normal.



Correct operation belonging to the check valve



In order to avoid excessive impact forces that are formed when the verify valve is closed, the valve need to be closed quickly to prevent the formation of any large reverse flow rate, which is the source of the impact pressure if your valve is suddenly closed. Therefore, the closing speed with the valve should match the attenuation speed of the downstream medium.



If the velocity of the downstream carrier varies widely, the minimum flow rate seriously isn't sufficient to force the closure to stop steadily. In this case, the movement of the closing member is usually suppressed by a damper just a certain range of it is stroke. The rapid vibration with the closing piece will cause the moving elements of the valve to tire too quickly, resulting in premature failure on the valve. If the medium is a pulsating flow, the rapid vibration of the closure is also a result of extreme media disturbances. In this case, the check valve really should be placed where the marketing disturbance is minimal.
https://www.hnvalves.com/products.html

2019年11月06日 10:58:58
テーマ: 未分類


コメント

コメント:0件
コメントはまだありません。


コメントを投稿する
書き込みには無料ユーザー登録が必要です。【ログイン】してください。